I. Model
Product name |
Full-auto infrared + light sensation two-in-one sensor |
Model |
AJT-RM-8VBL-2/M/H |
II. Features
● Full-auto sensing: The switch is turned on when people come and delays to turn off when people leave.
● Auto light measurement: 5 LUX- 500 LUX (adjustable). No sensing (factory default) when the light is strong, with light sensing adjustment (it can be adjusted to sensing under any light or all-climate sensing)
● Auto random delay (continuous delay mode): The switch is on all the time when people act within the sensing scope, and turns off until people leave.
● Non-continuous delay mode (optional) is also available and delay time is adjustable
III. Technical Parameters
1. Rated voltage: 220 VAC (50 Hz) □12 VDC □24 VDC
2. Ambient temperature: -20℃-+50℃
3. Self power consumption: <0.016 W
4. Load type: :□ Unipolarity: various lamps and exhaust fans; □ Bipolarity: Various lamps and electrical appliances
5. Load type: □ Bipolarity (resistance ≤1,000 W, sensibility ≤400 W, LED lamp or spotlight ≤200 W)
□ Unipolarity (resistance ≤200 W, sensibility 5-100 W)
□12 VDC (resistance ≤80 W, sensibility ≤40 W)
□24 VDC (resistance ≤200 W, sensibility ≤80 W)
6. Output form: Positive output (normally off, on upon sensing)
7. Light control scope (adjustable): 5 Lux - 500 Lux ± 20% (factory default is 5 LUX ± 20%)
8. Delayed off time (adjustable): 16-350 s ±30% (factory default is 16 s±30%)
9. Sensing scope diagram: (ground clearance is about 1.5 m in the case of wall mounting, and 2-4 m in the case of surface mounting)
10. Sensing distance: 5-12 m
IV. Wiring Diagram
V. Scope of Application
Automatic lighting of corridors, hallways, bathrooms, basements, warehouses and garages, automatic air drafting and the automatic control of other electrical appliances, and also applicable to guard of theft.